Circuit Breakers

Miniature Circuit-Breaker IEC Series 8562
Miniature Circuit-Breaker IEC Series 8562
  • 1 to 4 pole versions
  • Rated current from 0.5 ... 40 A
  • 6 or 10 kA breaking capacity to DIN VDE 0641, respectively EN 60898
  • Isolating Function to EN 60947-2
  • Permanently set thermal and magnetic trips
  • Power limitation class 3
ATEX / IECEx
Zone 0 1 2 20 21 22
For use in x x
Residual Current Circuit-Breaker Series 8562
Residual Current Circuit-Breaker Series 8562
  • Rated working current
    • 16 A
    • 25 / 40 A
  • Rated leakage current
    • 10 mA
    • 30 / 100 / 300 / 500 mA
  • For use in pulsed DC and AC currents
  • Protection against contact voltage
ATEX / IECEx
Zone 0 1 2 20 21 22
For use in x x
Residual Current Circuit-Breaker with Integral Overcurrent Protection FI/LS Series 8562
Residual Current Circuit-Breaker with Integral Overcurrent Protection FI/LS Series 8562
  • With residual current measurement and tripping device
  • With 2 pole switching miniature circuit-breaker for overload and short-circuit
ATEX / IECEx
Zone 0 1 2 20 21 22
For use in x x
Ex Miniature Circuit Breaker Series 8562
Ex Miniature Circuit Breaker Series 8562
  • 1, 2 and 3 Pole with Thermal-Magnetic Branch Circuit Protection
  • Rated current from 0.2 A ... 40 A
  • Protection Method: Flameproof for Class Zone1; AEx de IIC (US) Ex de IIC (C) and Class I Div 2 Grps A, B, C, D (US) Class I Div 2 Per CEC J 18-150
  • For use in US + Canada, in NEC / CEC applications.
Ground Fault Interrupter Series 8562
Ground Fault Interrupter Series 8562
  • Personell protection
  • Device protection
  • Rated operational current 16 / 25 / 35 A
  • Rated leakage current 10 / 30 / 300 mA
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
For use in x x For use in x x For use in x
Explosion-Protected Ground-Fault Protection, ExGFCI & ExGFEP Series 8565/11
Explosion-Protected Ground-Fault Protection, ExGFCI & ExGFEP Series 8565/11
  • ExGFCI: Explosion-protected Class A, ground-fault circuit-interrupter with over-current protection intended for protection of personnel
    • ANSI/UL 943 & 489 and CSA C22.2 No. 144-1 & No. 5
  • ExGFEP: Explosion-protected equipment protection with over-current protection
    • ANSI/UL 1053 & 489 and CSA C22.2 No. 144 & No. 5
  • Ambient temperature range -40 ... +40 °C (-40 ... +104 °F)
  • Test button to check continued proper device function
NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
For use in x x For use in x
Explosion-Protected Arc-Fault Protection ExAFCI - Arc-Fault Circuit Interrupter Series 8565/12
Explosion-Protected Arc-Fault Protection ExAFCI - Arc-Fault Circuit Interrupter Series 8565/12
NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
For use in x x For use in x